ANSMANN 5207452 Datasheet Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11

used for these batteries.

(see picture
E
)
CHARGE
Battery will be charged (battery icon is filled up from bottom
to top); when the battery is fully charged, the charged
capacity will be shown in the LCD display (3)
DISCHARGE
Battery will be discharged (battery icon is emptied from top
to bottom); when the battery is discharged, the discharged
capacity will be shown in the LCD display (3)
BATTERY-TEST
Battery will be charged, discharged and charged; when the
battery is fully charged, the discharged capacity will be shown
in the LCD display (3)
CYCLE
Battery will be charged and discharged with the adjusted
number of cycles (1-10); the pre-adjustment of cycles is 3
but by pushing the button ◂ (6), the number of cycles can
be reduced and by pushing the button ▸ (7), the number
of cycles can be increased. After the last cycle, the battery
will be fully charged and the last discharged capacity will be
shown in the LCD display (3)

The number “1…8” or battery type9VorLi-Ion” above
the battery icon indicates which battery currently is selected.
The display (3) indicated value always refers to the currently
selected battery. By pushing the button (6), the previous
battery or by pushing the button (7) the next battery can
be selected. After choosing the respective battery, it can be
selected by pushing the “OK(5) button. Then the icon of the
selected battery and the currently indicated value in the LCD
display (3) will flash. By pushing the button (6) or ▸ (7)
another parameter can be indicated. The following parameters
can be selected:
VOLTAGE Indication of the current battery voltage in V
CURRENT Indication of the current charge-/discharge current in mA
CAPACITY Indication of the current charged/discharged capacity in mAh
TIME Elapsed time of the current process
While a charge program is running, always the VOLTAGE of
the selected battery is indicated. When the charge program
for one battery ends, the indication switches automatically
in the view of this battery and shows the CAPACITY in the LCD
display (3). Another battery can be selected at any time by
pushing the button ◂ (6) or ▸ (7).

The charger is cooled by built-in fans. The fans run when at
least one round cell is charged or discharged. It is normal that
batteries may become warm during charging. After charging
of round cells and 9V E-Blocks is complete, the charger
switches automatically to trickle charge.

Once the charger is connected to mains, the battery tester is
ready for use. It is possible to charge rechargeable batteries
in the charger and to test batteries or rechargeable batteries
at the same time.

In the front of the charger is the test pin (1), which is only
needed for testing of round cells.
1. Select the appropriate test terminal for the battery under
test (see picture
A
).
2. Place the battery on the corresponding test terminal,
paying attention to the polarity (both contacts must be
connected). When checking round cells, the test pin (1)
always has to be connected to the negative pole of the
battery!
3. After both poles of a battery are contacted, in the display
(4) appears "CALC" (for about 2 seconds). Then the capacity
of the battery will be shown in 10% steps for approx.
2 seconds and for further 2 seconds the voltage of the
battery will be shown. As long as the battery is contacted,
the display changes between capacity and voltage (see
picture
D
).
Make sure that the contacts of the test terminals and the
contacts of the batteries are clean. With a new battery it is
possible that the full capacity may not be shown. The battery
needs to “wake up”. In this case please repeat the test again.

Do not dispose of the device in the normal household waste.
Please return it to your dealer or to your nearest recycling
centre or collection point. Please recycle all packing materials
for the sake of the environment.

To make sure that the charger works properly, please
keep the contacts in the charging slots free from dust or
contamination. To clean the unit, disconnect it from the mains
and use only a dry cloth. Repair may only be undertaken by
competent authorised dealers!
Page view 11
1 2 ... 7 8 9 10 11 12 13 14

Comments to this Manuals

No comments